Customization: | Available |
---|---|
Application: | Three Phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 100/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Function description of control circut terminal:
Type | Terminal | Name | Function Description |
Power Supply | +10V-GND | External +10 V power supply |
Provide +10 V power supply to the external unit. Generally, it provides power supply to external potentiometer with the resistance range of 1-5kΩ. Maximum output current:10mA |
+24V-COM | External +24 V power supply |
Provide +24 V power supply to the external unit. Generally, it provides power supply to DI/DO terminals and external sensors. Maximum output current:200mA |
|
Analog Input | AI1-GND | Analog input 1 | Input voltage range: 0-10 VDC Impedance: 22kΩ |
AI2-GND | Analog input 2 | Input range: 0-10 VDC/0-20mA, decided by jumper J1 on the control board Impedance: 22kΩ (voltage input),500 Ω (current input) |
|
Digital input | DI1- COM | Digital input 1 | Optical coupling isolation Impedance: 2.4kΩ Voltage range for level input: 9-30V |
DI2- COM | Digital input 2 | ||
DI3- COM | Digital input 3 | ||
DI4- COM | Digital input 4 | ||
DI5- COM | High-speed pulse input |
Besides features of DI1-DI4, it can be used for high-speed pulse input. Maximum input frequency: 100 kHz |
|
Analog output | AO1-GND | Analog output 1 | Voltage or current output is decided by jumper J2. Output voltage range: 0-10V Output current range: 0-20mA |
Digital output | DO1-COM | Digital output 1 | Optical coupling isolation, dual polarity open collector output Output voltage range: 0-24V Output current range: 0-50mA |
FM- COM | High-speed pulse output |
It is limited by P5-00 (FM terminal output mode selection). As high-speed pulse output, the maximum frequency hits 100 kHz. As open-collector output, its specification is the same as that of DO1 |
|
Relay Output | T/A-T/B | NC terminal | Contact driving capacity: 250VAC, 3A, COS ø=0.4 30VDC, 1A Applying to Overvoltage Category II circuit |
T/A-T/C | NO terminal | ||
Auxiliary interface |
J3 | 485 communication |
Jumper selection to decide whether to connect 330Ω matched resistor to make 485 communication |
J5 | External operation panel interface |
Connect to external operation panel. |
AC drive | Power capacity(kVA) | Input current A | Output current A | Adaptable Motor KW. HP |
|
Three-phase:380V,50/60HZ | |||||
AC900-4T0.75G | 1.5 | 3.4 | 2.1 | 0.75 | 1 |
AC900-4T1.5G | 3.0 | 5.0 | 3.8 | 1.5 | 2 |
AC900-4T2.2G | 4.0 | 5.8 | 5.1 | 2.2 | 3 |
AC900-4T3.0G | 5.0 | 8.0 | 7.0 | 3.0 | 4 |
AC900-4T4.0G | 5.9 | 10.5 | 9.0 | 4.0 | 5 |
AC900-4T5.5G | 8.9 | 14.6 | 13.0 | 5.5 | 7.5 |
AC900-4T7.5G | 11.0 | 20.5 | 17.0 | 7.5 | 10 |
AC900-4T11G | 17.0 | 26.0 | 25.0 | 11.0 | 15 |
AC900-4T15G | 21.0 | 35.0 | 32.0 | 15.0 | 20 |
AC900-4T18.5G | 24.0 | 38.5 | 37.0 | 18.5 | 25 |
AC900-4T22G | 30.0 | 46.5 | 45.0 | 22 | 30 |
AC900-4T30G | 40.0 | 62.0 | 60.0 | 30 | 40 |
AC900-4T37G | 57.0 | 76.0 | 75.0 | 37 | 50 |
AC900-4T45G | 69.0 | 92.0 | 91.0 | 45 | 60 |
AC900-4T55G | 85.0 | 113.0 | 112.0 | 55 | 70 |
AC900-4T75G | 114.0 | 157.0 | 150.0 | 75 | 100 |
AC900-4T90G | 134 | 180 | 176 | 90 | 125 |
AC900-4T110G | 160 | 214 | 210 | 110 | 150 |
AC900-4T132G | 192 | 256 | 253 | 132 | 175 |
AC900-4T160G | 231 | 307 | 304 | 160 | 250 |
AC900-4T200G | 250 | 385 | 377 | 200 | 300 |
AC900-4T220G | 280 | 430 | 426 | 220 | 300 |
AC900-4T250G | 355 | 468 | 465 | 250 | 400 |
AC900-4T280G | 396 | 525 | 520 | 280 | 370 |
AC900-4T315G | 445 | 590 | 585 | 315 | 500 |
AC900-4T355G | 500 | 665 | 650 | 355 | 420 |
AC900-4T400G | 565 | 785 | 725 | 400 | 530 |